Sensor Interface / PT100 RTD Sensor Node
PT100 RTD Sensor Node
The PT100 RTD Sensor Node enables precise temperature monitoring using a variety of sensors. The PT100 RTD can have an optional integrated IX triaxial tilt sensor for combined tilt and temperature sensing in one unit.
It uses the integrated radio transceiver to report its measurements through Senceive’s wireless communications network to a Gateway.
Typical temperature monitoring applications of the PT100 RTD Sensor Node include:
- Steel structures
- Rail, for critical rail temperature alerting
- Concrete structures, including during curing
- Heating, ventilation, and air conditioning (HVAC) systems
- Waterproof, robust connectors for simple installation
- Accuracy of 0.1°C
- Can have -IX triaxial tilt sensor integrated for combined tilt and temperature sensing in one unit
- Integrated long life battery
- 12-15 year battery life
- Versatile mounting options
- Waterproof to IP66 / IP67 / IP68
- Firmware is remotely upgradeable over the air via the gateway reducing costly site visits (FlatMesh)
- Easily deployed
FlatMesh PT100 RTD Sensor Node - FM3N-RTD
GeoWAN PT100 RTD Sensor Node - LR3N-RTD
FlatMesh Physical Specifications
Parameter | Value |
---|---|
Dimensions excluding antenna and vent | 90 x 90 x 60 mm |
Dimensions excluding antenna | 90 x 96 x 60 mm |
Total Mass | 0.57kg |
Housing Material | Die cast aluminium |
Protection (BS EN 60529: 1992 + A2: 2013) |
IP66 / IP67 IP68 at 1m for 24 hours |
Mounting Options | M4 blind holes in side ¼” UNF holes in bottom |
Operating Temperature Range | -40°C to +85°C |
RTD Interface
Parameter | Value |
---|---|
Connector | M12 Female 5-pole A-coded Screw-in Type |
Accuracy | ± 0.1°C |
Resolution | 0.01°C |
Stimulus Type | Constant Current |
Tilt Sensor (-IX variant only)
Parameter | Value |
---|---|
Resolution | 0.0001° (0.00175 mm/m) |
Repeatability | ±0.0005° (0.0087 mm/m) |
Range | ±90° |