Sensor Interface / PT100 RTD Sensor Node
PT100 RTD Sensor Node
The PT100 RTD Sensor Node enables precise temperature monitoring using a variety of sensors.
It uses the integrated radio transceiver to report its measurements through Senceive’s wireless communications network to a Gateway.
Typical temperature monitoring applications:
- Steel structures
- Rail, for critical rail temperature alerting
- Concrete structures, including during curing
- Heating, ventilation, and air conditioning (HVAC) systems
- Waterproof, robust connectors for simple installation
- Accuracy of 0.1°C
- Can have -IX triaxial tilt sensor integrated for combined tilt and temperature sensing in one unit
- Integrated long life battery
- 12-15 year battery life
- Versatile mounting options
- Waterproof to IP66 / IP67 / IP68
- Firmware is remotely upgradeable over the air via the gateway reducing costly site visits (FlatMesh)
- Easily deployed
FlatMesh PT100 RTD Sensor Node - FM3N-RTD
GeoWAN PT100 RTD Sensor Node - LR3N-RTD
FlatMesh Physical Specifications
Parameter | Value |
---|---|
Dimensions excluding antenna and vent | 90 x 90 x 60 mm |
Dimensions excluding antenna | 90 x 96 x 60 mm |
Total Mass | 0.57kg |
Housing Material | Die cast aluminium |
Protection (BS EN 60529: 1992 + A2: 2013) |
IP66 / IP67 IP68 at 1m for 24 hours |
Mounting Options | M4 blind holes in side ¼” UNF holes in bottom |
Operating Temperature Range | -40°C to +85°C |
RTD Interface
Parameter | Value |
---|---|
Connector | M12 Female 5-pole A-coded Screw-in Type |
Accuracy | ± 0.1°C |
Resolution | 0.01°C |
Stimulus Type | Constant Current |
Tilt Sensor (-IX variant only)
Parameter | Value |
---|---|
Resolution | 0.0001° (0.00175 mm/m) |
Repeatability | ±0.0005° (0.0087 mm/m) |
Range | ±90° |